Your parachute equipment takes a beating. Sweat, dirt, sand, grass, moisture, aircraft grime, and years of handling all leave their mark. But how much attention are you actually giving your gear when it comes to cleaning?


Clean gear is safe gear
Clean Gear is Safe Gear

As skydivers, we spend considerable time discussing canopy performance, reserve repack cycles, automatic activation devices, harness/container designs, and advancements in parachute technology. However, one of the simplest aspects of equipment ownership is also one of the most frequently overlooked: keeping our parachute equipment clean.


At Parachute Laboratories, Inc. (PLABS), we believe understanding how parachute equipment is constructed, maintained, and preserved is just as important as understanding how it operates.


Interestingly, some valuable guidance on this subject comes from a U.S. Air Force Technical Order published more than 37 years ago.


On July 1, 1989, the United States Air Force published Technical Order T.O. 14D1-1-2, Cleaning of Parachute Assemblies. This manual established standardized cleaning procedures for personnel parachutes, cargo parachutes, deceleration systems, and aerial delivery parachute assemblies.


Although the document was written for military applications, many of its underlying principles remain relevant to civilian skydiving equipment.


Let's examine what this historical technical order tells us, why it matters, and how these principles translate into maintaining modern parachute equipment.


WHY CLEANING YOUR PARACHUTE EQUIPMENT MATTERS


Parachute systems are built from specialized textiles, webbing, thread, hardware, coatings, and other materials designed to withstand specific operational loads and environmental conditions.


While these materials are engineered for demanding applications, they are not indestructible.


Over time, contamination can affect both the appearance and serviceability of equipment.


Consider what your parachute encounters throughout a typical jumping season:

  • Perspiration absorbed into shoulder straps, leg pads, and harness webbing.

  • Dirt and sand transferred from packing areas.

  • Grass stains, mud, and other environmental contaminants from landings.

  • Oil, grease, and hydraulic fluids encountered around aircraft and maintenance facilities.

  • Saltwater or freshwater exposure.

  • Dust and debris accumulating inside containers, deployment bags, and equipment pockets.

  • Moisture trapped in fabric, padding, and stitching.


Some of these contaminants are primarily cosmetic. Others can contribute to deterioration or interfere with mechanical components.


The 1989 technical order specifically recognized that parachute assemblies could become contaminated through handling and use between scheduled repacking periods.


It also recognized something that is often forgotten: cleaning should be performed when necessary, rather than subjecting equipment to unnecessary treatment simply because it looks used.


The objective is preservation, not merely appearance.

A clean parachute system is easier to inspect, maintain, and evaluate for damage. However, cleaning alone does not establish airworthiness, and a clean-looking component may still be unserviceable.


THE FIRST RULE: KNOW WHAT YOU ARE CLEANING

One of the most important lessons from T.O. 14D1-1-2 is that different parachute materials require different cleaning approaches.


A parachute assembly is not a single material.


Your harness/container may include nylon webbing, Cordura or other woven fabrics, padding, stainless-steel hardware, coated fabrics, plastic components, elastic materials, and specialty thread.


Your canopy may use low-porosity fabric, zero-porosity fabric, suspension lines, reinforcing tapes, and materials with their own manufacturing requirements.

The original military document specifically addressed differences among canopy fabric, harness webbing, cotton components, metal hardware, padding, and Lexan components.


That distinction remains important.


A cleaning process appropriate for one component may be completely inappropriate for another.


For example, a damp cloth may be appropriate for surface contamination on an approved harness/container fabric, while prolonged immersion or chemical exposure may affect coatings, padding, stitching, or other components.

Likewise, solvents that remove grease from metal may damage adjacent textiles.

This is why parachute manufacturers establish maintenance instructions for their specific equipment.


Before cleaning, determine exactly what material is contaminated and consult the applicable manufacturer's instructions.


SALTWATER: A CONTAMINANT THAT REQUIRES IMMEDIATE ATTENTION

One of the strongest warnings in the 1989 technical order concerns saltwater exposure.


Saltwater is particularly concerning because it can affect textile components and promote corrosion of metal hardware.


According to the historical military guidance, parachute assemblies exposed to saltwater required prompt attention, including cleaning and inspection of affected components.

The document also established strict removal-from-service criteria for certain contaminated or immersed components.


For civilian skydivers, the message is straightforward:

If your parachute system lands in saltwater, do not simply hang it up, let it dry, and assume everything is fine.


Salt deposits can remain inside fabric structures, stitching, hardware interfaces, and other difficult-to-access areas even after the equipment appears dry.


Saltwater exposure should trigger an evaluation of the entire affected assembly.

The original technical order emphasized cleaning and treating all potentially contaminated parachutes, inspecting for corrosion, and evaluating additional contamination such as oils or hydraulic fluids.


Today, an owner should contact the equipment manufacturer and an appropriately qualified parachute rigger before attempting restoration or returning the equipment to service.


Depending on the equipment, extent of exposure, and manufacturer's instructions, certain components may require replacement.


FRESHWATER: LESS AGGRESSIVE, BUT STILL A CONCERN

Freshwater exposure presents its own challenges.


A parachute that becomes wet from rain, an unexpected water landing, or improper storage requires appropriate drying and inspection.


The 1989 technical order described drying certain parachute assemblies by hanging them from their vent lines in a drying tower.


While most civilian skydivers do not have access to a military parachute drying tower, the underlying principle is relevant: equipment should be dried thoroughly using an appropriate method that does not introduce additional damage.


For today's harness/container systems, that generally means considering the manufacturer's drying requirements, providing adequate ventilation, and avoiding unnecessary heat or direct sunlight.


Do not assume that because the exterior fabric feels dry, the padding, internal webbing, or concealed portions of the assembly are equally dry.


Moisture can remain trapped within components.


Before returning exposed equipment to service, have it evaluated as required by the manufacturer and applicable maintenance procedures.


PERSPIRATION: THE CONTAMINATION WE CREATE OURSELVES

Let's address something every skydiver understands.


We sweat in our gear. A lot.


Whether you're making summer jumps in Florida, spending long days at a boogie, or working through an intensive training course, perspiration inevitably finds its way into your harness.


Shoulder straps, leg pads, chest straps, back pads, and other contact surfaces accumulate moisture, body oils, and dirt.


Over time, this can produce discoloration, odors, and deposits within the fabric.

The 1989 technical order specifically identified perspiration contamination as a condition requiring cleaning and subsequent inspection.


It also warned against aggressive cleaning methods that could damage harness materials.


For modern equipment, properly approved spot cleaning is often a practical starting point.


A clean cloth or soft brush, combined with a manufacturer-authorized cleaning solution, may be sufficient to remove ordinary surface contamination.

Avoid aggressive scrubbing, especially around exposed stitching, webbing edges, labels, and structural components.


The objective is to remove contamination without damaging the underlying material.

And remember, a harness that smells better after cleaning has not necessarily been properly inspected.


DIRT, MUD, SAND, AND DROP ZONE GRIME

If your equipment has spent years operating from grass landing areas, dusty packing mats, desert drop zones, or muddy fields, it probably carries evidence of that history.


The historical technical order addressed mud, dirt, sand, and general debris separately from more serious chemical contamination.


For ordinary loose contamination, its procedures included allowing equipment to dry and then removing debris with a soft brush.


That remains a useful principle when permitted by the manufacturer's instructions.


Dry sand and dirt can often be removed without introducing water or cleaning chemicals.


Pay particular attention to areas where debris may accumulate:

  • Container flaps and seams.

  • Corners of equipment pockets.

  • Harness adjustment areas.

  • Leg-pad and back-pad surfaces.

  • Deployment bag surfaces.

  • Areas surrounding hardware and other components.


Avoid forcing sand or dirt deeper into fabric, seams, or mechanical components.

If contamination has reached the reserve container, closing system, or other critical areas, consult a qualified rigger rather than treating the problem as a cosmetic cleaning task.


OIL, GREASE, AND HYDRAULIC FLUID: NOT YOUR ORDINARY DIRT

Petroleum-based contamination deserves special attention.


The 1989 technical order addressed oil, grease, hydraulic fluids, and other petroleum products as a separate category requiring specific cleaning and inspection.

These substances may penetrate fabric, affect certain materials, and introduce contamination that is not readily removed through ordinary washing.

The original military procedures included repeated cleaning of affected areas and subsequent rinsing.


However, those historical procedures should not be interpreted as blanket authorization to use modern household degreasers, solvents, or other chemicals on today's parachute systems.


Do not experiment with automotive degreasers, brake cleaner, gasoline, paint thinner, or unidentified cleaning products on parachute equipment.

Chemical compatibility varies significantly among materials.


When petroleum contamination is present, determine its source, isolate the affected equipment, and seek manufacturer guidance.


Some components may be recoverable through approved procedures. Others may require replacement.


A stain disappearing does not necessarily mean the contamination has been completely removed.


MILDEW AND FUNGUS: THE PROBLEM WITH IMPROPER STORAGE

Improper storage can create problems even when a parachute is not being jumped.


Equipment left damp inside a gear bag, stored in a humid environment, or exposed to condensation can develop mildew or fungal contamination.


The military technical order included procedures for addressing mildew and fungus using mild cleaning solutions, followed by thorough rinsing and drying.


For modern parachute assemblies, the specific cleaning solution and procedure must be verified against the manufacturer's instructions before use.


Visible mildew can indicate a larger moisture problem.


If contamination is extensive, embedded within padding, or accompanied by signs of material deterioration, the equipment should be inspected before any return to service.


Good preventive habits include allowing equipment to dry appropriately, storing it in a clean environment, and avoiding prolonged storage while damp.


Do not treat mold or mildew as merely an odor problem.


CANOPIES REQUIRE THEIR OWN CLEANING CONSIDERATIONS

A main or reserve canopy is not simply a large piece of fabric that can be thrown into a washing machine.


Modern parachute canopies involve precisely manufactured materials, stitching, reinforcing structures, and suspension lines.


The 1989 technical order permitted specified hand-washing procedures for certain assemblies, including careful agitation, rinsing, draining, and extended drying.

It also specifically cautioned against wringing water out of canopies or suspension lines.


The reasoning remains important.


Twisting, aggressive agitation, mechanical extraction, and improper handling can introduce unwanted stress into materials and construction.


The historical document also prohibited overall machine cleaning of parachute assemblies.


For modern civilian equipment, do not machine-wash a canopy unless its manufacturer explicitly authorizes the process.


Similarly, do not assume that a washing procedure approved for an older military canopy applies to a modern zero-porosity ram-air canopy.


Special attention should also be given to suspension lines, canopy coatings, and materials that may react differently to water or cleaning agents.


Cleaning should never become an uncontrolled experiment involving critical life-support equipment.


CLEANING YOUR HARNESS/CONTAINER

For many recreational skydivers, the harness/container is where most visible contamination accumulates.


Over the years, your equipment may develop darkened leg pads, stained shoulder straps, dirty back pads, and discoloration around frequently handled areas.

Some owners become concerned that this appearance means their equipment is approaching the end of its service life.


Not necessarily.


The 1989 technical order recognized that discoloration can occur through ordinary handling and use. It also explained that some dirt becomes embedded in nylon webbing and may be difficult to remove completely.


It specifically differentiated normal cosmetic discoloration from deterioration that would require action by inspection personnel.


That is an important distinction.


A dirty-looking harness is not automatically an unsafe harness, just as a spotless harness is not automatically a safe one.

The historical document included hand-cleaning procedures for certain harness assemblies using warm water, soap, and careful drying. It also prohibited machine washing and solvent cleaning of those harnesses.


Today's manufacturers may provide different authorized procedures based on their materials and designs.


For a thorough harness/container cleaning, a qualified rigger may need to remove detachable components and prepare the assembly according to the manufacturer's instructions.


This may include removing the main canopy and deployment components, reserve canopy and components, AAD components, and other removable accessories as appropriate.


However, do not attempt to disassemble the reserve system, remove an AAD installation, or alter critical rigging components unless qualified and authorized to do so.


The system must be properly inspected, reassembled, and returned to service under applicable instructions.


Cleaning the exterior is only part of the process.


DRYING: AN OFTEN-OVERLOOKED PART OF CLEANING

One theme repeated throughout T.O. 14D1-1-2 is the importance of drying.


The document specified drying procedures and warned against exposing certain parachute materials to sunlight during cleaning, drying, and storage.


It also cautioned against twisting or wringing materials to remove water.

These principles are worth remembering.


A poorly executed drying process can undermine an otherwise successful cleaning.

Modern equipment should be dried according to its manufacturer's instructions, with attention to adequate ventilation, appropriate temperatures, and protection from unnecessary ultraviolet exposure.


Avoid improvising with commercial dryers, heat guns, excessive heat, or other uncontrolled drying methods.


Make certain that internal padding, fabric layers, and concealed components have dried adequately before the system is repacked or stored.


THE DIFFERENCE BETWEEN CLEANING AND MAINTENANCE

There is an important distinction that deserves emphasis.


Cleaning is not the same as maintenance, and neither is a substitute for inspection.

A thorough cleaning may reveal damage that was previously hidden beneath dirt or staining.


During an appropriate post-cleaning inspection, a qualified rigger should consider the condition of webbing, stitching, fabric, hardware, and any components potentially affected by contamination or the cleaning process.


In some cases, an item may look significantly better after cleaning but still require repair or replacement.


The 1989 technical order repeatedly placed responsibility for evaluating cleaning outcomes and material condition on supervisory and inspection personnel.

That approach remains sensible today.


Parachute systems are life-support equipment, and decisions involving their continued serviceability should never be based on cosmetic appearance alone.


WHAT THIS 1989 TECHNICAL ORDER STILL TEACHES US

Looking back at this historical military publication, several lessons remain remarkably relevant.


First, different contaminants require different responses. Saltwater, ordinary dirt, perspiration, petroleum products, and mildew are not interchangeable cleaning problems.


Second, not all materials can be treated using the same procedure.


Third, cleaning can sometimes cause additional damage if inappropriate chemicals, temperatures, mechanical action, or drying practices are used.


Fourth, thorough inspection is a necessary part of evaluating contaminated equipment.


Finally, cleanliness should serve a practical maintenance purpose rather than becoming an exercise in making used equipment appear new.


The goal is not to remove every mark of a parachute's operational history.


The goal is to preserve the equipment, identify deterioration, and maintain its serviceability.


FINAL THOUGHTS: OLD GUIDANCE, MODERN METHODS, AND A LITTLE COMMON SENSE


Although T.O. 14D1-1-2, Cleaning of Parachute Assemblies, dated July 1, 1989, has since been absorbed into other military maintenance publications and superseded by newer procedures, its fundamental guidance remains worth discussing.


Materials have changed, equipment designs have evolved, and manufacturers have developed different approaches to cleaning and maintaining modern parachute systems.


Some of today's methods are considerably more convenient than those available decades ago.


For instance, one practical option sometimes discussed within the parachute community involves stripping a harness/container down to its basic removable components and taking the prepared assembly to a professional dry cleaner.


Depending on the shop and location, a cleaning service may cost around $35 and take only a couple of days.


However, that convenience comes with an important qualification.


The 1989 technical order specifically prohibited solvent cleaning of certain harnesses and prohibited dry cleaning of Lexan containers. Therefore, professional dry cleaning should never be treated as automatically acceptable for all parachute equipment.


Before using a dry-cleaning service, confirm that the equipment manufacturer authorizes the exact cleaning process, solvents, and handling methods. A traditional solvent-based dry-cleaning process may not be suitable, even when a cleaner is willing to accept the equipment.


A properly prepared harness/container may be suitable for certain professionally performed cleaning processes when those processes are specifically approved by its manufacturer.


The equipment must then be inspected and correctly reassembled by appropriately qualified personnel before returning to service.


Ultimately, whether you're cleaning a small area by hand, addressing environmental contamination, or arranging an approved professional cleaning, the principle remains unchanged:


Take care of your equipment, understand what you're working with, and never sacrifice material integrity for cosmetic appearance.


After all, your parachute doesn't have to look brand-new to perform its job.

But it absolutely needs to be maintained in a condition where it can.


PARACHUTE LABORATORIES, INC.

Manufacturing parachute systems since 1969.

Over 57 years of American parachute manufacturing heritage, combined with a continuing commitment to equipment knowledge, innovation, and education.


Historical Reference: U.S. Air Force Technical Order T.O. 14D1-1-2, Cleaning of Parachute Assemblies, July 1, 1989, Sections I and II.


Technical Disclaimer: This article is intended for industry education and historical reference. The cited military technical order is not a substitute for current manufacturer instructions, applicable FAA requirements, or qualified parachute-rigger judgment. Chemical treatments and cleaning methods described in historical publications should not be applied to modern equipment without appropriate manufacturer authorization. Cleaning does not constitute an airworthiness determination.

Comments


bottom of page